These pumps are designed for intermittent duty,though most models can be run
continuously for hours at a time. They are commonly used either to pressurize water
from an atmospheric tank, to deliver purified water to a specific point of use, or
simply to increase pressure when required.
These pumps can be controlled by either a pressure switch (“demand” mode) or an
external power control device (“delivery” mode). When required, an integrated
bypass can be incorporated to help regulate pressure levels
TYPICAL APPLICATIONS:
Water Treatment/RO
Beverage/Foodservice
Distillation Equipment
Agricultural Spraying
General Industrial
Automotive
POWER: Available motors from 12VDC to 230VAC, energy requirements between 25W-100W (depending on flow, pressure). Can be
used with compatible transformers and/or DC power supplies, to be ordered separately. Standard terminations are 12”, stripped
end leadwires. Connectors and power cords are also available.
ENVELOPE DIMENSIONS: Approximately 3”x 4”x 7”, weighing 6 lbs. MOUNTING: All positions. Standard offering is a steel mounting
base with four hollow rubber grommets. CONTROL OPTIONS: Internal Bypass (20-200 psi), Pressure Switch (40-100 psi)
FITTINGS: 5800 Series options include built-in 3/8”, 1/4", or 5/16” John Guest half cartridges. 7800 Series options include 3/8” or
1/2" hose barb, quick connect fittings.